FIRE RESISTANT CABLES

A trusted factory-direct supplier for all your LSZH and fire-resistant cable needs

Benefits of fire-resistant cables

CHINNE CABLE stands out as the premier option for LSZH (Low Smoke Zero Halogen) fire-resistant cables. Designed to ensure uninterrupted power supply under severe fire conditions, these cables are essential for keeping critical emergency systems operational, such as alarms, smoke extraction and forced ventilation units, emergency lighting and signaling, water pumps, inert gas networks, automatic door release mechanisms, video surveillance cameras, and more.

Go to products

Typical applications of FIRE RESISTANT CABLES

Select...
Emergency circuits Automatic door opening Fire alarm systems Video surveillance cameras Data Centres Tunnels Industrial facilities

Fire-resistant cables for emergency circuits

Specially designed for life-saving systems, fire-resistant cables maintain circuit integrity during fires, meeting stringent IEC 60331 and EN 50200 standards. Their mica tape and fire-retardant construction ensure continuous power to emergency lighting, alarms, and evacuation systems when it matters most.

Emergency circuits

Specially designed for life-saving systems, fire-resistant cables maintain circuit integrity during fires, meeting stringent IEC 60331 and EN 50200 standards. Their mica tape and fire-retardant construction ensure continuous power to emergency lighting, alarms, and evacuation systems when it matters most.

Automatic door opening

Critical for safe egress, fire-resistant cables maintain operation of automated doors during emergencies, complying with fire safety stringent standards. Their mica tape and fire-retardant construction ensure uninterrupted power to access control systems when fire threatens, facilitating safe evacuation through smoke doors and security barriers.

Fire alarm systems

Essential for life-saving detection, fire-resistant cables maintain alarm circuit integrity during emergencies, complying with fire safety stringent standards. Their mica tape and fire-retardant construction ensure uninterrupted signal transmission to control panels and notification devices when fire threatens, guaranteeing early warning and safe evacuation.

Video surveillance cameras

Critical for emergency monitoring, fire-resistant cables maintain CCTV operation during incidents, complying with fire safety stringent standards. Their mica tape and fire-retardant construction ensure continuous power and signal transmission to security cameras when fire threatens, preserving vital footage for emergency response and post-incident investigation.

Data Centres

Critical for uptime protection, fire-resistant cables maintain uninterrupted operation during incidents, complying with IEC 60331 and EN 50200 standards. heir mica tape and fire-retardant construction ensure continuous power to servers and network infrastructure when fire threatens, preventing data loss and minimizing downtime in mission-critical environments.

Tunnels

Critical for evacuation safety, fire-resistant cables maintain emergency systems during tunnel fires, complying with fire safety stringent standards. Their mica tape and fire-retardant construction ensure continuous power to ventilation, lighting and communication systems when needed most, enabling safe evacuation and firefighter access in confined underground spaces.

Industrial facilities

Essential for operational resilience, fire-resistant cables maintain power to critical industrial systems during fire emergencies. Their mica tape and fire-retardant construction ensure continuous operation of safety shut-down systems, control units and emergency lighting - preventing catastrophic failures and people evacuation in high-risk industrial environments.

A complete solution from Top Cable

  • High quality Cable manufacturer
    Cable manufacturer Top Cable is one of Europe's leading cable manufacturers which excels in providing best-in-class service.
  • Large
    cable stock
    Large cable stock Our large cable stock is always ready to be shipped around the globe.
  • Quality and
    Certificates
    Quality/Certificates In our state-of-the-art laboratories we subject our cables to stringent product testing and quality controls.
  • Best-in-class-service
    Best-in-class-service A friendly and eficcient sales team and our excellent logistics will satisfy your cable requirements.

Why choose fire-resistant cables?

  • Maintained Circuit Integrity During Fire

  • Protecting Assets and Infrastructure from fire hazards

  • Enhanced Fire Safety

  • Trusted Quality: cables from a recognized manufacturer

  • Technical expert support and after-sales service

  • Premium service and global logistics

Fire resistant cables FAQS (Frequent asked questions)

Fire-resistant cables can withstand fire conditions, allowing them to continue to operate even in the event of a fire. This is crucial for safety in buildings and infrastructure, as they help ensure that emergency systems, such as alarms and lighting, remain operational during a fire. Fire-resistant cables are commonly used in in public places such as: hospitals, tunnels, offices, production plants, laboratories, hotels, etc.

The Construction Product Regulation (CPR) lays down harmonized conditions for the marketing of construction products in the EU. This is achieved by providing a “common technical language” offering uniform methods to assess the performance of construction products and to compare the performance of products from different manufacturers in different countries.
These methods are compiled in harmonised standards or technical specifications. This common technical language is to be applied by:
• The manufacturers when declaring the performance of their products, but also by
• The authorities of Member States when specifying requirements for them, and by
• Their users (architects, engineers, constructors…) when choosing the products most suitable for their intended use in construction works.
Further information can be found here.

The standards that validate the fire resistance and Functional Integrity of our cables are EN 50200 and IEC 60331-2 (minimum 120 minutes at 840ºC), EN 50362 and IEC 60331-1 (minimum 180 minutes at 950ºC, category C) and BS6387 (category C,W & Z). Our cables are also certified according to NBN C30-004.

Fire resistant cables are a specific type of electrical cable designed to maintain its Functional Integrity during a fire for a certain period of time. Their purpose is to provide electrical power to critical equipment such as emergency light, smoke extractors, sprinklers, water pumps, fire fighting equipments and alarm systems in emergency situations.

Fire resistant cables are commonly installed in safety systems (emergency lights, smoke extractors, sprinklers, water pumps, fire fighting equipments and alarm systems) in all premises open to the public such as: airports, arenas, concert halls, department stores, offices, hotels. Its use is a must in and critical services such as tunnels, data centres, hospitals, etc.

The maximum temperature that fire resistant cables can withstand typically ranges from 90°C to 120°C under normal operating conditions. However, during a fire, they are designed to maintain functionality at higher temperatures, often up to 950°C for a limited duration, depending on the specific type and standards of the cable. It’s important to check the manufacturer’s specifications for the exact ratings of a particular cable.

At Top Cable we have our own laboratories where we carry out all kinds of standarized tests on our cables, including fire resistance tests. You can find out more details in this post on our blog.

Fire-resistant cables maintain its Functional Integrity during a fire for a certain period of time, while fire retardant cables focus on slowing down flame spread. Both play important roles in fire safety, but they serve different purposes! Both are low smoke and halogen free: in the event of fire. f you have more questions about this topic, feel free to ask!

Low smoke halogen free (LSZH) cables have been designed to provide maximum protection to people and equipment in the event of fire. They are specially recommended for:
. Hospitals
. Offices, Universities, Schools
. Malls, Supermarkets, Shops in general, museums
. Trains.
. Ships, Submarines.
. Railway, road, & tunnel systems.
. Nuclear power stations
and much more.

Questions? We’ll help you find a solution.

CONTACT
topcable cub